Light Duty Stainless Steel Multistage Centrifugal Water Pump

Pump Description:

CDL / CDLF is a kind of vertical multi-functional products.It can be used to convey various medium from tap water to industrial liquid at different temperature and with different flow rate and pressure. CDL type is applicable to conveying non-corrosive liquid, while CDLF is suitable for slightly corrosive liquid.


Product Detail

Product Tags

 

water pompen

 

Pump Description

CDL / CDLF is a kind of vertical  multi-functional products.It can be used to convey various medium from tap water to industrial liquid at different temperature and with different flow rate and pressure. CDL type is applicable to conveying non-corrosive liquid, while CDLF is suitable for slightly corrosive liquid.

Application

1)  Water Supply: water filter and transport in waterworks, boosting of main pipeline, boosting in high-rise buildings.

2)  Industrial Boosting: process flow water system, cleaning system, high-pressure washing system, fire fighting system.

3)  Industrial Liquid conveying: cooling and air-conditioning system, boiler water supply and condensing system,machine-associated purpose, acids and alkali.

4)  Water Treatment: ultra filtration system.

5)  Reverse Osmosis System.

6)  Distillation System, separator, swimming pool.

7)  Irrigation: Farmland irrigation, spray irrigation, dripping irrigation

 

Performance Range

Capacity: 2 up to 500m³/h

Head: 15 up to 195 m

Efficiency : 72% up to 92.5%

Rotation Speed: 2900 r/min

Power: 0.37 up to 15 kw

NPSH: 1.8

 

Operation Conditions

1) Thin, clean, non-flammable and non-explosive liquid containing no solid granules and fibers.

2)  Liquid temperature:  Normal temperature type:-15℃~ +70℃ ;   Hot water type:-15℃~ +120℃

3) Ambient temperature: up to +40℃

4) Altitude:up to 1000m

5) When the density or viscosity of the transmission medium exceeds that of water, it is necessary to select a driving motor of high-power.

6) PH 5-8

Special demands can be negotiated.  

 

Motor

1. Full-enclosed air cooled type two-pole standard motor

2. Protection Class: IP55

3. Insulation Class: F

4. Standard Voltage: 50Hz: 1 x 220-230 / 240V
3 x 200-220 / 346-380V
3 x 220-240 / 380-415 V
3 x 3 80-415 V

 

General Technical Data

Model

Motor(kw

Q

m³/h

7

8

9

10

11

12

13

14

15

16

CDL12-2

1.5

Hm

23.5

23

22.5

22

21

20

18.5

17

15.5

14

CDL12-3

2.2

35.5

35

34

33

31.5

30

28

26

23.5

21

CDL12-4

3

47

46

45

44

42

40

37

34

31

28

CDL12-5

3

59.5

58

56.5

55

52.5

50

46.5

43

39

35

CDL12-6

4

71.5

70

68

66

63

60

56

52

47

42

CDL12-7

5.5

83.5

82

79.5

77

73.5

70

65.5

61

55

49

CDL12-8

5.5

95.5

94

91

88

84

80

75

70

63

56

CDL12-9

5.5

108

106

103

100

95.5

91

85

79

71.5

64

CDL12-10

7.5

120

118

114.5

111

106

101

94.5

88

80

72

CDL12-12

7.5

143.5

141

137

133

127

121

113.5

106

96

86

CDL12-14

11

168

165

160

155

148

141

132.5

124

112

100

CDL12-16

11

192.5

189

183.5

178

170

162

152

142

128.5

115

CDL12-18

11

217

213

207.5

202

192.5

183

171.5

160

145

130

 

Model Symbols

model symbols D

model symbols 20

Performance Curve 

Following conditions are suitable for the performance curves shown bellow:

1. All curves are based on the measured values of 50Hz: constant motor speed 2900rpm or 2950rpm.

2. Curve tolerance in conformity with 1SO9006 Annex A.

3. Measurement is done with 20℃air-free water. kinematic viscosity of mm2/sec.

4. The operation of pump shall refer to the performance region indicated by the thickened curve to prevent overheating due to too small flow rate or overload of motor due to too large flow rate.

General Data 

untitled

 

 

untitled

 

Installation  Dimension

 

Model

Dimensionmm

Weightkg
B1 B2 B1+B2 D1 D2
  CDL12-2 379 290 669 190 155 37
  CDL12-3 409 290 669 190 155 40
  CDL12-4 449 325 774 197 165 47
  CDL12-5 479 325 804 197 165 48
  CDL12-6 509 335 844 230 188 58
  CDL12-7 559 430 989 260 208 76
  CDL12-8 589 430 1019 260 208 76
  CDL12-9 619 430 1049 260 208 78
  CDL12-10 649 430 1079 260 208 78
  CDL12-12 709 430 1139 260 208 80
  CDL12-14 859 505 1364 330 255 151
  CDL12-16 919 505 1424 330 255 151
  CDL12-18 979 505 1484 330 255 153

Additional Data

untitled

 

untitled

contact

 


  • Previous:
  • Next:

  • WhatsApp Online Chat !