  • water pump motor fault reason and analysis

                                                                               Motor Fault Analysis 一、How to identify motor coil fault : When the motor coil burns out,  it means that the insulation of the motor coil is damaged, this will cause short-circuit tripping a...
    Maca deui
  • PUMP MOTOR FAULT ANALYSIS -04)

    四、conclusion 1、When the switch trips and the power is not run, the insulation resistance of the motor should be checked with a multimeter to confirm that there is no problem before running the power again; 2、Whether the power failure motor is burnt out (1)Check the three-phase coil of the  ...
    Maca deui
  • pump motor fault analysis -03)

    Difference of insulation damage and fault analysis 1、coil Short circuit (11)most of the coil is good, partial burn out ,as the picture shown (2)Cause analysis ①the insulation layer of wire is damaged and  When the motor is used, the coil voltage exceeds the breakdown voltage, then the insul...
    Maca deui
  • Motor Fault Analysis-02)

    三、Difference of insulation damage and fault analysis 1、coil Short circuit (1)most of the coil is good, partial burn out ,as the picture shows (2)Cause analysis ①the insulation layer of wire is damaged and  When the motor is used, the coil voltage exceeds the breakdown voltage, then the ...
    Maca deui
  • Motor Fault Analysis -1)

    一、How to identify motor coil fault : When the motor coil burns out,  it means that the insulation of the motor coil is damaged, this will cause short-circuit tripping after the coil is energized. Motor coil insulation damage include: Short circuit between coil turns Motor phase burnout Moto...
    Maca deui
  • Horizontal and Vertical Multistage Centrifugal Pumps

    Horizontal Multistage Centrifugal Pumps This type of pump has a segmented casing with modular inter-stage components. The rotating assembly is held between bearing housings, making the assembly more balanced for high pressures.   They typically handle higher flow rates than vertical multistage pu...
    Maca deui
  • what is multistage centrifugal water pump used for ?

            Multistage centrifugal pumps have been one of the most popular types of pumps in recent years. Their ability to provide engineers with a flexible range of flow and head, along with their high degree of energy efficiency makes them a great choice for many applications....
    Maca deui
  • What is Mag Drive Pump Work?

    Lets briefly discussion how mag drive pumps work All mag drive pumps compose of two components: the outer mag assembly and the impeller The mag-drive pump eliminates the direct drive mechanism and replaces it with a magnetic field. An outer magnetic bell housing is mounted on the end of the pump ...
    Maca deui
  • how about pump model selection principle?

    1. Make the type and performance of the selected pump meet the requirements of process parameters such as flow, lift, pressure, temperature and suction. 2, must meet the requirements of the media characteristics. For pumps that transport flammable, explosive, toxic or valuable media, it is requi...
    Maca deui
  • water pump selection principle?

        1. Make the type and performance of the selected pump meet the requirements of process parameters such as flow, lift, pressure, temperature and suction. 2, must meet the requirements of the media characteristics. For pumps that transport flammable, explosive, toxic or valuable media...
    Maca deui
  • how about pump model selection??

    First, list the basic data: 1. Characteristics of the medium: medium name, specific gravity, viscosity, corrosivity, toxicity, etc. 2. The particle diameter and content of the body contained in the medium. 3. Medium temperature: (°C) 4. The required flow rate The general industrial pump can ignor...
    Maca deui
  • SOG makes Water Flow more wonderful

          Shanghai SOG Pump Co., Ltd. (abbreviated as SOG) was founded in 2005. It’s dedicated to manufacture high-quality pumps and engaged in  providing “high-quality, high-efficiency, energy-saving, and environmental-friendly” pumps. It is the Innovative leading en...
    Maca deui
  • WQGS sewage pump malfunction analysis and elimination

      Installation, operation and maintenance tips   ●It is forbidden to pull cables with force in the installation and removal of electric pump to aovid wires breaking and joint delinking which lead to normal operation failure and even burns; ●Please ensure correct and reliable cable eart...
    Maca deui
  • SOG makes flow more powerful

    Life is born of water, the flow bring water more powerful. The condensation of human wisdom creats the pump. like a heart, giving the world nourishment, and endless life. SOG Specializing in pumps, is committed to quality and service. SOG Established in 2005, It is a subsidiary of Shanghai Rab...
    Maca deui
  • Installation note for vertical inline pump?

            Installation note for vertical inline pump? 1 Do not let the pump subjected to the-pipeline weight in erection, or it may be easy to be made damaged. 2 Both pump and motor are integrally structured and calibrated by the manufacture, so there is no need to adjust them,...
    Maca deui
  • horizontal chemical process pump characteristics

        General Description   CZ series chemical process pump are horizontal, single stage, end suction type centrifugal pumps,It was designed according to international standard ISO2858 ,size and performance meet ASME B73.1.ISO 05199. series. Can-transferring  liquids like low or hig...
    Maca deui
  • If Pump Failure, What’s is the Cause Reason and Solution.

      The Pump failure, cause reason and solution. 1. The pump can’t suction water and Pressure gauge is pumping ceaselessly. Reason: 1) Water filling isn’t enough  2) Air trapping in pump chamber,  then pipe are leaking. Solution: 1) Fill the water sufficiently  2)Check pipeline and eliminate a...
    Maca deui
  • The catetan instalasi keur stainless steel pompa centrifugal multilengkah

    The catetan instalasi keur stainless steel pompa centrifugal multilengkah

    The Catetan Instalasi pikeun steel Steel multilengkah centrifugal Kongrés: 1. Ti téhnologi instalasi pompa centrifugal multilengkah stainless steel, pipa nyeuseup merlukeun kaayaan segel ketat, moal bisa boga pipa bocor atanapi leakage, disebutkeun eta bakal ngancurkeun gelar vakum di abdi cai ...
    Maca deui
  • Naon cara uji pompa centrifugal?

    Naon cara uji pompa centrifugal?

    Biasana, The centrifugal Kongrés Test Di antarana Tipe Test na Factory Test: The pompa centrifugal test ─ tipe test nguji Tipe ngawengku: ngajalankeun test, test kinerja sarta uji captivation sarta uji Geter noise, jsb A: The test jalan Nalika ngajalankeun test, kudu parios kebangkitan suhu pompa ...
    Maca deui
  • Centrifugal pangropéa pompa dibagi kana primér sarta sekundér, jeung eusi husus bakal kaasup?

    Centrifugal pangropéa pompa dibagi kana primér sarta sekundér, jeung eusi husus bakal kaasup? Centrifugal tingkat pompa 1 eusi pangropéa saperti kieu: 1) mariksa jeung pastikeun yén packing teu pondok, kelenjar unbiased, teu maké jeung leakage mangrupa super kerah; 2) mariksa naha aya ...
    Maca deui
  • Awas! Ngompa boga situasi di handap ieu kudu geuwat ngeureunkeun!

    "Lamun manggihan salah sahiji titik handap kudu eureun pompa" (1) pompa The gaduh leakage cai; (2) Lamun motor tina pompa smokes atanapi nangkeupan seuneu; (3) Kongrés gaduh sora abnormal; (4) Lamun di hawa bearing naék-up teuing gancang atawa smokes; (5) Lamun pompa nu gaduh Geter kuat;
    Maca deui
WhatsApp Online Chat !